The industry standard for weld preheat, interpass and post-weld heat treatment verification for over 80 years. Mark the surface — the crayon melts the instant it hits its rated temperature, giving instant, calibration-free confirmation. 100–650°F, ±1% NIST-traceable, AWS D1.1 & ASME compliant. Supplied across the UAE, Qatar, Saudi Arabia and wider GCC.
Product Overview
What It Is
The Tempilstik is the original temperature-indicating crayon — a stick calibrated to melt at one precise temperature. Streak it across a heated surface: below the rating the mark stays dry and chalky; the moment the surface reaches the rated temperature the mark melts into a clear liquid smear. This gives an instant, calibration-free, ±1% NIST-traceable confirmation that the target temperature has been reached. Trusted on the most critical jobs for over 80 years.
Who Uses It
Welders, welding inspectors (CSWIP/AWS-CWI), QA/QC engineers, and heat-treatment technicians on structural, pipeline, pressure vessel and fabrication projects across the UAE, Qatar, Saudi Arabia, Kuwait and Oman. Mandatory on any weld with a specified preheat or interpass temperature in the WPS.
Where It Is Used
Weld preheat verification before striking an arc, interpass temperature control between weld passes, and post-weld heat treatment (PWHT) monitoring — across oil & gas, pipeline, petrochemical, structural steel, shipbuilding and power projects throughout the GCC. Also for bearing fitting, curing, drying, and any process needing surface temperature confirmation.
📋 Code Compliance — Why Inspectors Insist on Tempilstik
Welding codes mandate a minimum preheat and maximum interpass temperature to prevent hydrogen-induced cracking and control weld metallurgy. Tempilstik complies with the preheat temperature requirements of AWS D1.1, ASME Code Sec. I, III and VIII, and ANSI/ASME B31.1 and B31.3. The part number, temperature and lot code are imprinted across the entire stick for full inspection traceability — and the crayons are free of sulphur, lead and halogen, so they are safe on stainless steel and nickel alloys.
How to Use a Tempilstik
Select the Right Temperature
Choose the Tempilstik rated at your required preheat or interpass temperature (per your WPS). Each stick is a single fixed temperature.
Mark the Surface
As the surface heats, streak the crayon on the metal near (but not in) the weld zone. Below the rated temperature the mark is dry and chalky.
Watch for the Melt
The instant the surface reaches the stick's rated temperature, the mark melts into a distinct liquid smear — your visual "go" signal that temperature is reached.
Verify & Weld
Confirm melt across the required area, then proceed with welding. For interpass control, check between passes that the surface has NOT exceeded the maximum interpass stick.
Temperature Range & Common Ratings
Common Preheat / Interpass Temperature Ratings (Full Range 100–650°F)
| °F | °C (approx.) | Typical Application |
|---|---|---|
| 100°F | 38°C | Low-temp drying / minimum preheat |
| 150°F | 66°C | Light preheat, thin section |
| 175°F | 79°C | Common minimum preheat |
| 200°F | 93°C | Standard structural preheat |
| 250°F | 121°C | Preheat — medium section |
| 300°F | 149°C | Preheat — heavy section / higher CE steel |
| 350°F | 177°C | Preheat — thick / high-strength steel |
| 400°F | 204°C | Preheat / interpass control |
| 450°F | 232°C | Interpass max control |
| 500°F | 260°C | Interpass / high-preheat alloy |
| 550°F | 288°C | High preheat / PWHT approach |
| 600°F | 316°C | Interpass max / heat treatment |
| 650°F | 343°C | Upper standard range / PWHT |
Additional temperatures below 100°F and above 650°F are available. Confirm the exact rating required by your WPS. Contact us with your temperatures and we'll supply the matching sticks.
Key Features & Benefits
±1% NIST-Traceable Accuracy
Precise, calibration-free temperature indication with 100% reliability — no meters to calibrate, no batteries, no drift. The melt point is the measurement. Trusted by inspectors as objective evidence of temperature compliance.
Code Compliant & Traceable
Meets AWS D1.1, ASME Sec. I/III/VIII, and ANSI/ASME B31.1/B31.3 preheat requirements. Part number, temperature and lot code imprinted across the entire stick — full traceability for QA/QC documentation and audits.
Instant Visual Result
The mark melts the moment the surface hits the rated temperature — an immediate, unambiguous go/no-go signal. No waiting, no interpretation. Faster and cheaper than contact thermometers for spot checks.
Sulphur, Lead & Halogen Free
Free of contaminants that cause cracking or corrosion in stainless steel and nickel alloys — safe to use directly near the weld zone on corrosion-resistant alloys and critical service pipework.
Slip-Resistant Aluminium Holder
The crayon is supplied in a slip-resistant aluminium holder for safe, controlled handling near hot surfaces — advancing the stick as it wears, like a mechanical pencil.
Works on Almost Any Surface
Usable on steel, iron, aluminium, stainless steel, glass, plastic and ceramic — one tool across welding, bearing fitting, curing, drying and general surface temperature checks in any industry.
Applications by Industry
| Application | Detail |
|---|---|
| Oil & Gas — Pipeline Welding | Preheat and interpass verification on pipeline and process pipe welding to API 1104 / ASME B31.3, mandatory on ADNOC (UAE), Aramco (Saudi Arabia), QatarEnergy (Qatar), KOC (Kuwait) and PDO (Oman) projects |
| Structural Steel | AWS D1.1 preheat confirmation on structural welding for buildings, bridges and industrial structures across the GCC and Africa |
| Pressure Vessels & Boilers | ASME Section I/VIII preheat and interpass control on pressure vessel, heat exchanger and boiler fabrication in petrochemical and power projects |
| Post-Weld Heat Treatment | Monitoring approach and hold temperatures during PWHT of welded joints on critical service pipework and vessels |
| Shipbuilding & Offshore | Preheat verification on hull, structural and piping welds in shipyards and offshore module fabrication across UAE, Saudi Arabia and Qatar |
| Maintenance & General | Bearing and gear fitting temperature checks, drying/curing verification, and general surface temperature confirmation in plant maintenance |
Frequently Asked Questions
What is a Tempilstik and how does it work?
Why are Tempilstiks used in welding preheat and interpass control?
What temperature range and accuracy do Tempilstiks offer?
What surfaces can Tempilstik be used on?
How can I get pricing in UAE, Qatar, Saudi Arabia, Kuwait or Oman?
📲 WHATSAPP FOR BEST PRICING — +971 55 697 6535
View Our Global Service Network (GCC & Middle East)
Ruwais · Jebel Ali.
Mesaieed · Al Wakrah.
Jubail · Yanbu · Khobar.
Manama (Bahrain).
Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.
We want you to be 100% satisfied with your purchase. Items can be returned or exchanged within 30 days of delivery.