Dynaweld Venturi Blower Dubai UAE
-
Estimated Delivery:Apr 30 - May 04
-
Free Shipping & Returns: On all orders over $75
Dynaweld Venturi Blower Dubai UAE
Dynaweld Venturi Blowers
Compressed air or steam powered ventilation blowers with absolutely no moving parts. Operates on the Venturi principle — moving large volumes of air from a small compressed air or steam input. Engineered for confined space ventilation, tank purging, process vessel exhaust, and hazardous atmospheric locations across the Middle East and Africa.
Product Overview
⚙ How the Venturi Principle Works
What It Is
The Dynaweld Venturi Blower is a no-moving-parts ventilation device powered by compressed air or dry saturated steam. Using the Venturi principle, it converts a small input of high-velocity air or steam into a large volume of airflow — suitable for supplying fresh air into or exhausting contaminated air from confined spaces, tanks, vessels, and enclosed work areas.
Who Uses It
Specified by HSE engineers, confined space supervisors, process engineers, and safety managers in oil & gas, petrochemical, marine, shipbuilding, foundry, and construction industries. Procured by operations teams across the UAE (ADNOC), Saudi Arabia (Aramco, SABIC), Iraq (Basra), Qatar, Kuwait, Nigeria (NNPCL), Kenya, and South Africa for confined space and process safety applications.
Where It Is Used
Designed for tanks, towers, refineries, process plants, pressure vessels, cooling and drying applications, foundries, sandblasting operations, shipyards, manholes, cargo holds, and all confined work areas. Capable of moving large volumes of air through long duct runs. Suitable for hazardous atmospheric locations where electrical equipment is prohibited.
Model Range — DY2, DY4, DY6, DY8
DY2
COMPACTDY4
STANDARDDY6
HEAVY DUTYDY8
MAX CAPACITYTechnical Specifications
Blower Dimensions — All Models
| Model | Length (A) | Base Dia. (B) | Horn Dia. (C) | Thread NPT (D) | Bolt Circle (E) | Slot Dia. (F) | Net Weight |
|---|---|---|---|---|---|---|---|
| DY2 | 28" | 7.25" | 6.25" | 1/2" | 6" | 0.4" (3 slots) | 5.5 lbs |
| DY4 | 33.25" | 7.25" | 7.34" | 1/2" | 6.56" | 0.4" (3 slots) | 8.5 lbs |
| DY6 | 44.5" | 11.5" | 12" | 1" | 10.50" | 0.4" (3 slots) | 22.3 lbs |
| DY8 | 46" | 17.25" | 14" | 1" | 13.62" | 0.5" (4 slots) | 36.0 lbs |
Air Consumption (SCFM) at Operating Pressures
| Model | 60 PSIG | 80 PSIG | 100 PSIG |
|---|---|---|---|
| DY2 | 30 SCFM | 40 SCFM | 50 SCFM |
| DY4 | 30 SCFM | 40 SCFM | 50 SCFM |
| DY6 | 60 SCFM | 80 SCFM | 100 SCFM |
| DY8 | 110 SCFM | 140 SCFM | 180 SCFM |
Total Airflow (CFM) at Operating Pressures
| Model | 60 PSIG | 80 PSIG | 100 PSIG |
|---|---|---|---|
| DY2 | 865 CFM | 1,080 CFM | 1,205 CFM |
| DY4 | 1,135 CFM | 1,310 CFM | 1,465 CFM |
| DY6 | 2,560 CFM | 3,020 CFM | 3,700 CFM |
| DY8 | 4,215 CFM | 4,810 CFM | 5,435 CFM |
Static Pressure (IWC) at Operating Pressures
| Model | 60 PSIG | 80 PSIG | 100 PSIG |
|---|---|---|---|
| DY2 | 5.8 IWC | 7.5 IWC | 8.8 IWC |
| DY4 | 5.8 IWC | 7.5 IWC | 8.8 IWC |
| DY6 | 4.2 IWC | 5.6 IWC | 6.5 IWC |
| DY8 | 4.0 IWC | 5.2 IWC | 6.2 IWC |
Free Air Induction Rates & Noise Levels
| Model | Free Air Induction @ 60 PSI | Free Air Induction @ 80 PSI | Free Air Induction @ 100 PSI | Noise @ 5ft — 60 PSI (dB) | Noise @ 5ft — 80 PSI (dB) | Noise @ 5ft — 100 PSI (dB) |
|---|---|---|---|---|---|---|
| DY2 | 28.83 | 27.00 | 24.10 | 66 dB | 68 dB | 71 dB |
| DY4 | 37.83 | 32.75 | 29.30 | 69 dB | 72 dB | 73 dB |
| DY6 | 42.67 | 37.75 | 37.00 | 73 dB | 75 dB | 78 dB |
| DY8 | 38.32 | 34.36 | 30.19 | 77 dB | 79 dB | 81 dB |
Key Features & Benefits
| Feature | Benefit |
|---|---|
| No Moving Parts | Zero mechanical wear — no bearings, no blades, no rotating components. Eliminates maintenance requirements and failure modes associated with moving parts. Longest possible service life in demanding industrial environments across the Gulf and Africa. |
| Hazardous Area Safe | No electric motor, no spark source, no ignition risk. Suitable for use in ATEX-classified zones, explosive atmospheres, H₂S environments, and flammable vapour locations where electric or mechanical ventilation equipment cannot be used. |
| Compressed Air or Steam Powered | Operates on the compressed air supply already present on most industrial sites — no additional power source required. Can also operate on dry saturated steam where available in refinery and petrochemical plant environments. |
| Supply or Exhaust Operation | Reversal of the blower orientation switches between blowing fresh air in and exhausting contaminated air out — a single unit serves both confined space pre-entry purging and during-work ventilation needs. |
| Long Duct Run Capability | The Venturi design generates sufficient static pressure to push air through extended duct runs to remote confined spaces — suitable for ventilating deep tanks, long horizontal vessels, and underground structures. |
| 4-Model Range (DY2–DY8) | Airflow capacity from 865 CFM to 5,435 CFM — select the appropriate model based on vessel volume, required air changes per hour, and available compressed air supply capacity. |
| Compact & Lightweight (DY2/DY4) | DY2 at 5.5 lbs and DY4 at 8.5 lbs are easily portable for field use — suitable for maintenance teams and confined space entry teams working across multiple locations. |
| Conical Diffuser | Precisely controls air direction and expansion rate — improves ventilation efficiency and ensures airflow is directed to where it is needed within the confined space or vessel. |
| Wide Operating Pressure Range | Performs effectively at 60, 80 and 100 PSIG — flexible across different site compressor outputs and air supply conditions encountered across Middle East and Africa industrial sites. |
Applications by Industry
| Industry | Application |
|---|---|
| Oil & Gas — Upstream | Pre-entry purging and ventilation of storage tanks, production separators, pressure vessels, and wellhead enclosures before confined space entry — operations across UAE (ADNOC), Saudi Arabia (Aramco), Iraq (Basra, Baghdad), and Nigeria (NNPCL) |
| Refineries & Petrochemical | Fume and vapour extraction from towers, reactors, process vessels, and column internals during turnaround and maintenance shutdowns in Ruwais, Dammam, Jeddah, Lagos, and Basra refineries |
| Offshore Platforms | Confined space and below-deck ventilation on offshore platforms — air-powered operation is mandatory where electrical equipment is not permitted in potentially explosive atmospheres |
| Marine & Shipbuilding | Tank and hold ventilation, fume extraction during painting, blasting, and welding inside ship structures — widely used in shipyards across UAE, Ghana, Nigeria, and South Africa |
| Sandblasting Operations | Abrasive dust and contaminated air extraction from sandblasting enclosures, blast chambers, and vessel interiors during surface preparation work |
| Foundries | Heat, fume, and particulate ventilation in casting and moulding areas where compressed air is the primary energy source |
| Cooling & Drying | Directed airflow for cooling hot surfaces and process equipment, or drying vessel interiors after cleaning, hydrotesting, or chemical treatment |
| Manholes & Underground | Ventilation of manholes, underground utility vaults, pump sumps, and culverts before and during entry for maintenance teams across Egypt, Kenya, Tanzania, and South Africa |
| Construction & Tunnelling | Ventilation of tunnel faces, underground construction areas, and enclosed building voids where no electrical supply is available |
Operating Media & Safety Precautions
Operating Media
| Parameter | Specification |
|---|---|
| Recommended Media | Compressed air or dry saturated steam only |
| Maximum Operating Pressure | 150 PSI (10.3 bar) |
| Rated Operating Pressures | 60, 80 and 100 PSIG |
| Other Gases / Liquids | Extreme caution required — use only compressed air or dry saturated steam. Not recommended for other compressed gases or liquids. |
⚠ Safety Precautions — Read Before Use
- Ensure the unit is connected to suitable ground connections. When mounted on non-conductive adaptors or used free-standing, a bonding cable must be used.
- The unit must be firmly positioned and secured before compressed air or steam is admitted to the nozzle chamber — high reaction forces are generated during operation.
- Do not allow solid objects or loose debris to enter the inlet housing during operation.
- When exhausting fumes from tanks and process vessels, take care to avoid creating vacuum conditions that could collapse the tank or vessel — ensure adequate air make-up is provided.
Frequently Asked Questions
How does a Dynaweld venturi blower work?
What is the difference between models DY2, DY4, DY6 and DY8?
Can the venturi blower be used in explosive or hazardous atmospheres?
What compressed air supply is required to operate the venturi blower?
How can I get pricing for Dynaweld venturi blowers in UAE, Saudi Arabia, Iraq or Africa?
For pricing on any model (DY2, DY4, DY6 or DY8):
📲 WHATSAPP FOR BEST PRICING — +971 55 983 6563
View Our Global Service Network (MENA & Africa)
Riyadh, Jeddah, Dammam (Saudi Arabia).
Doha (Qatar) · Muscat (Oman) · Kuwait City · Bahrain.
Amman (Jordan).
Algiers (Algeria).
Casablanca (Morocco).
Nairobi (Kenya).
Dar es Salaam (Tanzania).
Accra (Ghana) · Uganda.
Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.
We want you to be 100% satisfied with your purchase. Items can be returned or exchanged within 30 days of delivery.